  1. BOARD
  2.     ID = "DEC0600"
  3.     NAME = "Digital PCMCIA/IR Adapter Card" 
  4.     MFR = "Digital Equipment Corporation"
  5.     CATEGORY = "MFC"
  6.     SLOT = ISA16
  7.     COMMENTS = "Digital PCMCIA/IR Adapter Card\n"
  8.     VERSION = 1.00
  9.  
  10. JUMPER(1) = 7
  11.     NAME = "J5"
  12.     JTYPE = PAIRED
  13.     VERTICAL = NO
  14.     REVERSE = NO
  15.     LABEL = LOC(7-1) "14" "12" "10" "8" "6"  "4" "2"
  16.     FACTORY = LOC(0100000
  17.  
  18.  GROUP = "PCMCIA/IR ISA Adapter"
  19. FUNCTION = "PCMCIA"
  20.     TYPE = "PCM"
  21.     SUBFUNCTION = "I/O Port Address"
  22.         CHOICE = "200h"
  23.             FREE
  24.             PORT = 200h-20Fh
  25.             SHARE = NO
  26.             INIT = JUMPER(1) LOC(7-1) 1000000
  27.         CHOICE = "240h"
  28.             FREE
  29.             PORT = 240h-24Fh
  30.             SHARE = NO
  31.             INIT = JUMPER(1) LOC(7-1) 0100000
  32.         CHOICE = "280h"
  33.             FREE
  34.             PORT = 280h-28Fh
  35.             SHARE = NO
  36.             INIT = JUMPER(1) LOC(7-1) 0010000
  37.         CHOICE = "2C0h"
  38.             FREE
  39.             PORT = 2C0h-2CFh
  40.             SHARE = NO
  41.             INIT = JUMPER(1) LOC(7-1) 0001000
  42.         CHOICE = "300h"
  43.             FREE
  44.             PORT = 300h-30Fh
  45.             SHARE = NO
  46.             INIT = JUMPER(1) LOC(7-1) 0000100
  47.         CHOICE = "340h"
  48.             FREE
  49.             PORT = 340h-34Fh
  50.             SHARE = NO
  51.             INIT = JUMPER(1) LOC(7-1) 0000010
  52.         CHOICE = "380h"
  53.             FREE
  54.             PORT = 380h-38Fh
  55.             SHARE = NO
  56.             INIT = JUMPER(1) LOC(7-1) 0000001
  57.  
  58. FUNCTION = "IR communication Port"
  59.     TYPE = "COM"
  60.     CHOICE = "IR Port"
  61.         FREE
  62.         PORT = 398h-399h
  63.         SHARE = NO
  64.         PORT = 3F8h-3FFh
  65.         SHARE = NO
  66.         IRQ = 4
  67.  
  68. ENDGROUP 
  69.